{"id":62170,"date":"2024-03-12T08:25:22","date_gmt":"2024-03-12T12:25:22","guid":{"rendered":"https:\/\/fenomax.com\/?p=62170"},"modified":"2025-04-28T15:50:26","modified_gmt":"2025-04-28T19:50:26","slug":"quebec-basement-window-egress-standards","status":"publish","type":"post","link":"https:\/\/fenomax.com\/en\/quebec-basement-window-egress-standards\/","title":{"rendered":"Basement Windows: Quebec Standards (2025)"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">The safety of your home is paramount. That\u2019s why it is essential to comply with safety standards for windows, especially basement windows. You must follow the Egress standard from the National Building Code.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In this article, we will discuss the regulations for basement windows and their future implications. It\u2019s important to understand that these rules are mandatory laws designed to ensure everyone\u2019s safety \u2014 not just recommendations.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Basement windows must allow for quick and effective evacuation in emergencies, such as fires or floods. By following these rules, you comply with local laws and create a safe environment for yourself and your family.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Consult the construction code at L\u00e9gis Qu\u00e9bec here.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Summary Table of Standards and Regulations for Basement Windows<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Here\u2019s a comprehensive but summarized list of standards and regulations for basement windows. For more detailed information, keep reading!<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Criterion<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Description<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Purpose of the Egress Standard<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Protect the health and safety of occupants by ensuring an adequate emergency exit.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">National Building Code Requirement<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Every bedroom must have at least one window or door with direct outside access unless an automatic sprinkler system is installed.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Characteristics of a Compliant Window<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Easily accessible, large, and can be opened without keys, tools, or special knowledge.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Minimum Dimensions<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Clear opening of at least 0.35 m\u00b2, with each side measuring at least 380 mm.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Installation Height<\/span><\/td>\n<td><span style=\"font-weight: 400;\">No more than 150 cm from the floor, or a fixed piece of furniture must be installed to facilitate evacuation.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Window Well<\/span><\/td>\n<td><span style=\"font-weight: 400;\">If present, must provide at least 760 mm clearance. In winter, clear snow from in front of the window.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Opening System<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Must not obstruct clearance. For casement windows, the pivot must not restrict opening.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Window Well Cover<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Must open from the inside without tools or special knowledge.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Compliance Check<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Multiply the height by the width of the clear opening; it must equal or exceed 0.35 m\u00b2.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Local Standards<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Local regulations may be stricter than the National Building Code; check with your municipality.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">New Construction<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Basement windows are not required to meet Egress standards if no bedroom is planned.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Impact on Resale Value<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Compliance can increase a home\u2019s resale value.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Tip<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Always refer to the National Building Code to ensure your project complies with the Egress standard.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"font-weight: 400;\">Safety Standards for Basement Bedrooms<\/span><\/h2>\n<h3><span style=\"font-weight: 400;\">Are There Window Requirements for Emergency Exits?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Yes. Bedrooms must have a window or door leading outside for safety in case of fire. Emergency exit windows must be easily accessible, appropriately sized, and able to open without keys or special equipment. It is recommended to regularly clear snow from around the windows during winter to ensure emergency exit access.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">Should I Take Additional Precautions for Emergency Exits?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Absolutely. Family members should know how to open the windows. Ensure that windows are not blocked by furniture or decorations, allowing quick evacuation if needed. Windows should also be designed to resist break-ins, enhancing overall home security. Following these guidelines can help prevent accidents and ensure your home remains a safe place.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">What Are the Specific Regulations for Basement Emergency Exits?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Basement bedroom windows must have at least a 3.75 square foot opening and a minimum height of 15 inches, allowing an adult to exit during an emergency.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Basement Window Safety Standards<\/span><\/h2>\n<h3><span style=\"font-weight: 400;\">Is There a Staircase Safety Standard Related to Basement Windows?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Yes. Basement stairs must be equipped with a smoke detector. The minimum dimensions for basement windows are critical to ensure easy emergency evacuation. Windows must be easy for everyone to open, including children and the elderly.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">Should We Practice Emergency Evacuation?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Yes. It\u2019s recommended to conduct evacuation drills so that everyone in the house knows what to do in an emergency. These practices can save lives in real situations requiring quick and orderly evacuation.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">Is It Necessary to Leave the Lights On at Night for Safety?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">No, it is not necessary to leave all lights on overnight to ensure safety if you need to exit through a basement window.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Construction Standards for Basement Windows According to the National Building Code<\/span><\/h2>\n<h3><span style=\"font-weight: 400;\">What Is the Building Code?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">The National Building Code sets construction standards applicable throughout Quebec. It defines minimum window sizes. Read more about window measurement here.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">Is the Code Frequently Updated?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Yes, the National Building Code is regularly updated to enhance building safety and energy efficiency.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">Why Is Compliance Important?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Keeping your basement windows compliant with current standards and regulations is critical for homeowners to ensure safety and legal conformity.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Standard Dimensions and Requirements for Basement Windows, Including Egress Windows<\/span><\/h2>\n<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Window Element<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Description<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Minimum Window Sizes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">The minimum clear opening must be 0.35 m\u00b2, and neither width nor height can be less than 380 mm.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Installation Height<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Ideally less than 1.5 meters from the floor. If not possible, install a low-height piece of furniture to facilitate access.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Functionality as Emergency Exits<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Requirements ensure windows serve effectively as emergency exits when needed.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">What Are the Legal and Safety Implications for Basement Bedrooms Concerning Window and Emergency Exit Requirements?<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Legal implications are mainly governed by the Egress standard under the National Building Code and local regulations. These rules ensure that bedrooms have adequate openings for safe evacuation in emergencies like fires.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Table of Legal Implications for Basement Bedroom Windows and Emergency Exits<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">It is advised to verify specific municipal standards and ensure all installations meet requirements to avoid consequences such as:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Fines or Penalties: Municipal authorities or the R\u00e9gie du b\u00e2timent du Qu\u00e9bec can impose fines if installations do not meet the Egress standard.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Insurance Issues: Insurance companies may require compliance for proper coverage. Non-compliance could limit or void coverage in the event of a claim.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Impact on Resale Value: Non-compliance can lower a property&#8217;s resale value, as potential buyers and inspectors may view it as a risk or additional cost.<\/span><\/li>\n<\/ul>\n<h2><span style=\"font-weight: 400;\">How to Properly Install a Basement Window According to Egress Standards and the Building Code<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Here\u2019s a table summarizing key steps and important considerations for installing a compliant basement window. Always consult local specifications and your region\u2019s current building code to ensure full compliance.<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Step<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Sub-Attributes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Description<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Planning<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Standards and Regulations<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Verify local Egress and building code requirements for window size and type.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Window Selection<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Choose a window that meets minimum size requirements and can be easily opened from the inside without tools.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Installation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Placement<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Ensure the window is installed no higher than 1.5 meters from the floor or provide a step.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Clearance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Provide a minimum clearance (usually at least 760 mm) in front of the window for easy evacuation.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Opening Mechanism<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Choose windows with simple mechanisms that do not obstruct emergency opening.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Verification<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Opening Size<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Measure the opening to confirm it meets the 0.35 m\u00b2 minimum area.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Access and Functionality<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Test the window to ensure it opens easily from the inside without keys, tools, or special knowledge.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Compliance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Inspection<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Schedule an inspection by local authorities to validate compliance with Egress standards and the building code.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Documentation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Keep records proving compliance for insurers or resale purposes.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"font-weight: 400;\">Conclusion<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">In conclusion, it is crucial to comply with safety standards for basement windows. These standards protect the health and safety of occupants by ensuring proper emergency exits. Non-compliance can lead to municipal inspections and fines.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Insurance companies may also require Egress-compliant windows for proper coverage. It\u2019s vital to prioritize safety standards for all home windows, especially those in basements.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Invest in quality windows to ensure your home\u2019s safety, appearance, and long-term value. Listen to expert advice to make the right choice.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Remember, safety is critical for your home. Always prioritize it in all construction and maintenance work.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">FAQ \u2013 Basement Window Dimensions<\/span><\/h2>\n<h3><span style=\"font-weight: 400;\">What Are the Standards for Basement Windows in Quebec?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">In Quebec, basement windows must meet the Building Code, especially if they serve as emergency exits. They must have a minimum opening of 0.35 m\u00b2, with at least 38 cm in height and width, and be openable without tools.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">What Is a Basement Window Called?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">A basement window is often called an egress window or a vent window. If it is designed as an emergency exit, it is specifically referred to as an egress window.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">How to Install a Basement Window?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Steps for installing a basement window:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Measure the existing opening or create a new one if necessary.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Prepare and level the frame.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install the window with screws and apply external sealing for waterproofing.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Add a window well or drainage system to prevent water infiltration.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">What Is the Minimum Size for a Basement Window?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">For emergency exits, a basement window must be at least 38 cm high and wide, with a free opening area of at least 0.35 m\u00b2.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">Is a Window Well Required for a Basement Window?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Yes, a window well is often recommended, especially if the ground is close to the window opening. It prevents water infiltration and ensures clear emergency exit access.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">What Type of Window Should You Choose for a Basement?<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">PVC or aluminum windows with double or triple glazing are ideal for basements because they offer good thermal insulation and moisture resistance. Casement or awning models are often preferred for their sealing effectiveness.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Discover 2025 basement window and Egress requirements in Quebec to protect your family, comply with laws, and increase your home\u2019s value.<\/p>\n","protected":false},"author":2,"featured_media":6258,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Quebec Basement Window Rules and Egress Standards","_seopress_titles_desc":"Learn about Quebec\u2019s 2025 basement window regulations and Egress standards to ensure safety, legal compliance, and boost your home\u2019s resale value.","_seopress_robots_index":"","_seopress_analysis_target_kw":"","inline_featured_image":false,"footnotes":""},"categories":[1228],"tags":[],"class_list":{"0":"post-62170","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-window-buying-guide"},"acf":[],"acfml_non_translatable_locations":null,"_wp_attached_file":null,"_wp_attachment_metadata":null,"wpml_media_processed":null,"_wpml_media_usage":null,"_elementor_inline_svg":null,"_elementor_source_image_hash":null,"_wp_attachment_image_alt":null,"region":null,"region_courte":null,"cmplz_hide_cookiebanner":"","_seopress_social_fb_title":null,"_seopress_social_fb_desc":null,"_seopress_social_twitter_title":null,"_seopress_social_twitter_desc":null,"_seopress_social_fb_img":null,"_seopress_social_fb_img_attachment_id":null,"_seopress_social_fb_img_width":null,"_seopress_social_fb_img_height":null,"_seopress_social_twitter_img":null,"_seopress_social_twitter_img_attachment_id":null,"_seopress_social_twitter_img_width":null,"_seopress_social_twitter_img_height":null,"logo":null,"_logo":null,"adresse_1":null,"_adresse_1":null,"adresse_2":null,"_adresse_2":null,"ville":null,"_ville":null,"code_postal":null,"_code_postal":null,"website":null,"_website":null,"google_map":null,"_google_map":null,"_icl_lang_duplicate_of":null,"_elementor_screenshot_failed":null,"__elementor_forms_snapshot":null,"_seopress_robots_follow":null,"_elementor_location":null,"_elementor_priority":null,"_elementor_code":null,"_elementor_extra_options":null,"prosomo_franchise_franchise_pages_checkbox":null,"prosomo_franchise_get_pages_checkbox":null,"address":null,"_address":null,"city":null,"_city":null,"country":null,"_country":null,"postal_code":null,"_postal_code":null,"email":null,"_email":null,"phone":null,"_phone":null,"fax":null,"_fax":null,"main_google_maps":null,"_main_google_maps":null,"get_hours":null,"_get_hours":null,"google_maps_0_name":null,"_google_maps_0_name":null,"google_maps_0_map":null,"_google_maps_0_map":null,"google_maps":null,"_google_maps":null,"place_id":null,"_place_id":null,"prosomo_franchise_seo_use_template":null,"service_icon":null,"prosomo_franchise_google_review_cache":null,"prosomo_franchise_google_review_cache_date":null,"sunday_start_hour":null,"_sunday_start_hour":null,"sunday_start_minute":null,"_sunday_start_minute":null,"sunday_end_hour":null,"_sunday_end_hour":null,"sunday_end_minute":null,"_sunday_end_minute":null,"sunday":null,"_sunday":null,"monday_start_hour":null,"_monday_start_hour":null,"monday_start_minute":null,"_monday_start_minute":null,"monday_end_hour":null,"_monday_end_hour":null,"monday_end_minute":null,"_monday_end_minute":null,"monday":null,"_monday":null,"tuesday_start_hour":null,"_tuesday_start_hour":null,"tuesday_start_minute":null,"_tuesday_start_minute":null,"tuesday_end_hour":null,"_tuesday_end_hour":null,"tuesday_end_minute":null,"_tuesday_end_minute":null,"tuesday":null,"_tuesday":null,"wednesday_start_hour":null,"_wednesday_start_hour":null,"wednesday_start_minute":null,"_wednesday_start_minute":null,"wednesday_end_hour":null,"_wednesday_end_hour":null,"wednesday_end_minute":null,"_wednesday_end_minute":null,"wednesday":null,"_wednesday":null,"thursday_start_hour":null,"_thursday_start_hour":null,"thursday_start_minute":null,"_thursday_start_minute":null,"thursday_end_hour":null,"_thursday_end_hour":null,"thursday_end_minute":null,"_thursday_end_minute":null,"thursday":null,"_thursday":null,"friday_start_hour":null,"_friday_start_hour":null,"friday_start_minute":null,"_friday_start_minute":null,"friday_end_hour":null,"_friday_end_hour":null,"friday_end_minute":null,"_friday_end_minute":null,"friday":null,"_friday":null,"saturday_start_hour":null,"_saturday_start_hour":null,"saturday_start_minute":null,"_saturday_start_minute":null,"saturday_end_hour":null,"_saturday_end_hour":null,"saturday_end_minute":null,"_saturday_end_minute":null,"saturday":null,"_saturday":null,"localbusiness_name":null,"_localbusiness_name":null,"localbusiness_description":null,"_localbusiness_description":null,"localbusiness_image":null,"_localbusiness_image":null,"prosomo_franchise_original_id":null,"prosomo_franchise_page_id":null,"_prosomo_franchise_template_id":null,"_prosomo_franchise_remove_menu_link":null,"_prosomo_franchise_remove_menu_completely":null,"_prosomo_franchise_menu_class":null,"prosomo_franchise_template_id_copy":null,"_prosomo_franchise_template_id_copy":null,"prosomo_franchise_link_only":null,"_prosomo_franchise_link_only":null,"prosomo_franchise_link":null,"_prosomo_franchise_link":null,"_listing_data":null,"_listing_type":null,"_is_deps_ready":null,"_is_style_deps":null,"_is_script_deps":null,"metform_form__form_setting":null,"_metform_cloned_id":null,"ml-slider_settings":null,"metaslider_slideshow_theme":null,"_menu_item_type":null,"_menu_item_menu_item_parent":null,"_menu_item_object_id":null,"_menu_item_object":null,"_menu_item_target":null,"_menu_item_classes":null,"_menu_item_xfn":null,"_menu_item_url":null,"jet_menu_settings":null,"jet-menu-item":null,"_content_type":null,"_oembed_a4889b747f138ed09635b2500c9ce9d5":null,"_oembed_time_a4889b747f138ed09635b2500c9ce9d5":null,"_oembed_80936e6cd6ba3506ec27a42fea006a60":null,"_oembed_time_80936e6cd6ba3506ec27a42fea006a60":null,"_form":null,"_mail":null,"_mail_2":null,"_messages":null,"_additional_settings":null,"_locale":null,"_ctz_zapier":null,"_hash":null,"wpcf7_id":null,"wpcf7_rule_id":null,"action_type":null,"post_title":null,"page_id":null,"external_url":null,"http_build_query_selectively_fields":null,"delay_redirect_seconds":null,"action_status":null,"_wpml_media_featured":"1","_wpml_media_duplicate":"1","_edit_lock":"1745869841:2","_edit_last":"2","_wp_old_slug":null,"_thumbnail_id":"6258","inline_featured_image":null,"_seopress_analysis_data":null,"_seopress_redirections_type":"301","_seopress_redirections_logged_status":"both","_wp_page_template":"default","_elementor_edit_mode":null,"_elementor_template_type":"wp-post","_elementor_version":"3.19.1","_elementor_pro_version":null,"_elementor_data":null,"_elementor_page_assets":[],"_wpml_word_count":"1668","_wpml_location_migration_done":null,"_wpml_media_has_media":"1","_seopress_analysis_target_kw":"","_cmplz_scanned_post":null,"_elementor_css":null,"_dp_original":null,"_top_nav_excluded":null,"_cms_nav_minihome":null,"_elementor_template_widget_type":null,"_last_translation_edit_mode":"native-editor","_elementor_controls_usage":null,"_seopress_titles_title":"Quebec Basement Window Rules and Egress Standards","_wp_old_date":null,"_seopress_titles_desc":"Learn about Quebec\u2019s 2025 basement window regulations and Egress standards to ensure safety, legal compliance, and boost your home\u2019s resale value.","province":null,"_province":null,"_elementor_conditions":null,"_eael_custom_js":null,"_happyaddons_elements_cache":null,"_elementor_popup_display_settings":null,"_elementor_page_settings":null,"_seopress_robots_index":null,"_oembed_314d4a3db169cc32bd2a344be9b486d8":null,"_oembed_time_314d4a3db169cc32bd2a344be9b486d8":null,"_oembed_0018718db84f5fbf1571ea95aa5e9cb9":null,"_oembed_time_0018718db84f5fbf1571ea95aa5e9cb9":null,"prosomo_franchise_template_id":null,"prosomo_franchise_seo_title":null,"prosomo_franchise_seo_description":null,"prosomo_franchise_seo_social_image":null,"prosomo_franchise_remove_menu_completely":null,"prosomo_franchise_remove_menu_link":null,"prosomo_franchise_menu_class":null,"_links":{"self":[{"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/posts\/62170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/comments?post=62170"}],"version-history":[{"count":0,"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/posts\/62170\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/media\/6258"}],"wp:attachment":[{"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/media?parent=62170"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/categories?post=62170"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fenomax.com\/en\/wp-json\/wp\/v2\/tags?post=62170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}